LIFT POWER BACKUP SYSTEM

Product visuals may differ from the actual item.*

2.2 kVA LIFT INVERTER

Application areas

➤ Residential Elevators
➤ Hydraulic Lifts
➤ Commercial Low-Rise Buildings
➤ Hospital & Clinic Lifts
➤ Villa Elevators
➤ Home Dumbwaiter Lifts
➤ Goods Lifts (Small Capacity)

Product features:

➤ Advanced DSP-based Pure Sine Wave Technology for precise control & smooth lift operation
➤ High Starting Torque Support for elevator motors
➤ Fast Changeover (<10 ms) ensures lift doesn’t jerk or stop during power failure
➤ Compatible with both Single Phase Input & Single Phase Output
➤ High Surge Capability to start lift motors without overloading
➤ Wide Input Voltage Range for unstable power conditions
➤ Inbuilt MCB Protection & Smart LCD Display
➤ Pure Sine Wave Output ensures smooth motor rotation
➤ Intelligent Battery Charging System for extended battery life
➤ Overload & Short Circuit Protection
➤ Inbuilt Isolation for enhanced safety
➤ Customizable Backup Options as per lift requirement
➤ Easy Installation & Maintenance-Friendly Design

PARAMETER — TECHNICAL SPECIFICATION
Model 2.2 kVA Lift Inverter
Rating 2200 VA
AC INPUT
Voltage 230V AC ± 20%
Frequency 50Hz ± 6%
Phase Single Phase
DC INPUT / BATTERY
DC Voltage 24V DC
Battery Type SMF / VRLA / Lithium Compatible
Charger Type CC-CV Intelligent Charger
Charging Current 10A (Adjustable)
INVERTER
Technology DSP-Based PWM Sine Wave
Output Voltage 230V AC
Voltage Regulation ±1%
Output Frequency 50Hz ± 0.1Hz
Waveform Pure Sine Wave
Efficiency > 90%
Overload 110% for 5 minutes, 150% for 30 seconds
Motor Starting Capability High surge support
Crest Factor 3:1
DISPLAY
LCD Display Showing Input Voltage
Output Voltage
Output Load %
Battery Voltage
Battery Status
Fault Conditions
GENERAL
Operating Temperature 0°C – 45°C
Humidity < 95% Non-Condensing
Noise Level < 50 dB at 1 meter
Enclosure Powder-Coated MS Sheet
Cooling Forced Air Cooling
PROTECTIONS
Input Over/Under Voltage
Output Overload
Short Circuit Protection
Battery Deep Discharge
Battery Overcharge
Over Temperature Protection
Reverse Polarity Protection
INDICATIONS & ALARMS
Mains ON
Inverter ON
Battery Low
Overload Alarm
Fault LED + Buzzer
Charging ON
OPTIONAL FEATURES
RS232 / RS485 Communication
SNMP Module
Auto-Bypass System
Fire-Retardant Enclosure
High Backup (Extended Battery Bank)

Product visuals may differ from the actual item.*

3.5 kVA LIFT INVERTER

Application areas

➤ Residential & Mid-Rise Building Elevators
➤ Home Lifts & Hydraulic Lifts
➤ Small Commercial Elevators
➤ Hospital Bed Lifts (Compact Models)
➤ Goods Lifts (Light Duty)
➤ Dumbwaiter Elevators
➤ Escalator Control Backup Panels

Product features:

➤ DSP-controlled Pure Sine Wave Output for smooth elevator motor operation
➤ High Surge Capability to handle motor starting current
➤ Ultra-Fast Transfer Time (<10 ms) — ensures lift does not jerk
➤ Wide Input Voltage Range suitable for low grid areas
➤ Rugged Design for commercial elevator usage
➤ Intelligent CC-CV Battery Charging System
➤ Pure Sine Output ensures smooth & vibration-free lift travel
➤ Inbuilt MCB & Multiple Electronic Protections
➤ Heavy-Duty Output Transformer for reliability
➤ Compatible with SMF, VRLA & Lithium (LiFePO4) battery banks
➤ Easy Installation & Low Maintenance Design
➤ Optional Auto-Bypass for enhanced safety

PARAMETER — TECHNICAL SPECIFICATION
Model 3.5 kVA Lift Inverter
Rating 3500 VA
AC INPUT
Voltage 230V AC ± 20%
Frequency 50Hz ± 6%
Phase Single Phase
DC INPUT / BATTERY
DC Voltage 48V DC
Battery Type SMF / VRLA / Lithium Compatible
Charger Type Intelligent CC-CV Charger
Charging Current 10A / 15A (Model Dependent)
INVERTER
Technology DSP-Based IGBT PWM
Output Voltage 230V AC
Voltage Regulation ±1%
Output Frequency 50Hz ± 0.1Hz
Waveform Pure Sine Wave
Efficiency > 90%
Harmonic Distortion <3% on Linear Load
Overload 110% for 10 minutes, 150% for 30 seconds
Motor Starting Capability High surge support
Crest Factor 3:1
Isolation Output Isolation Transformer
DISPLAY
LCD Display Showing Input Voltage
Output Voltage
Output Current / Load %
Battery Voltage
System Temperature
Fault Conditions
GENERAL
Operating Temperature 0°C – 45°C
Humidity < 95% Non-Condensing
Noise Level < 50 dB at 1 meter
Enclosure Powder-Coated Metal Sheet
Cooling Intelligent Forced Cooling System
PROTECTIONS
Mains Over/Under Voltage
Output Overload
Output Short Circuit
Battery Deep Discharge
Battery Overcharge
Heat Protection
Reverse Battery Polarity
Output Over Temperature
INDICATIONS & ALARMS
Mains ON LED
Inverter ON LED
Charging ON LED
Battery Low Alarm
Overload Alarm
Fault Indication + Buzzer
OPTIONAL FEATURES
Auto-Bypass
RS232 / RS485 Communication
SNMP Interface
Emergency Rescue Device (Lift Lowering)
Extended Battery Bank Options
Fire-Retardant Cabinet

Product visuals may differ from the actual item.*

5 kVA LIFT INVERTER

Application areas

➤ Residential Lifts (High Load)
➤ Commercial Building Elevators
➤ Small Industrial Goods Lifts
➤ Hospital Duty Elevators
➤ Hydraulic Home Elevators
➤ Passenger Lifts up to 6–8 passengers
➤ Escalators & Lift Control Panels
➤ Freight Lifts with Light Load Capacity

Product features:

➤ Advanced DSP-based Pure Sine Wave technology
➤ High Starting Torque Support for lift motors
➤ Ultra-Fast Transfer (<10 ms) ensuring jerk-free lift operation
➤ High Surge Capacity ideal for induction motor startup
➤ Wide Input Voltage Range for unstable mains supply
➤ Robust Output Isolation Transformer
➤ Intelligent CC-CV Charger for long battery life
➤ Pure Sine Wave output for smooth motor control
➤ Heavy-Duty IGBT-based Inverter Stage
➤ Overload, Short-Circuit & Over Temperature Protection
➤ Compatible with SMF/VRLA/LiFePO4 battery banks
➤ Engineered for continuous commercial use
➤ Easy front-access design for maintenance
➤ Optional Auto-Bypass for seamless lift operation

PARAMETER — TECHNICAL SPECIFICATION
Model 5 kVA Lift Inverter
Rating 5000 VA
AC INPUT
Voltage 230V AC ± 20%
Frequency 50Hz ± 6%
Phase Single Phase
DC INPUT / BATTERY
DC Voltage 48V / 96V (Model Variant)
Battery Type SMF / VRLA / Lithium (LiFePO4)
Charger Type Intelligent CC-CV Charging
Charging Current 12A / 15A / 20A
INVERTER
Technology DSP + IGBT PWM Controlled
Output Voltage 230V AC
Voltage Regulation ±1%
Output Frequency 50Hz ± 0.1Hz
Waveform Pure Sine Wave
Efficiency > 90%
Harmonic Distortion <3% on Linear Load
Overload 110% for 10 min
150% for 30 sec
Crest Factor 3:1
Motor Starting Capability Strong surge support
Isolation Galvanic Isolation Output Transformer
Audible Noise <50 dB at 1 meter
DISPLAY
LCD Display Shows Input Voltage
Output Voltage
Output Load %
Battery Voltage
System Temperature
Charging Status
Faults & Alarms
GENERAL
Operating Temperature 0°C – 45°C
Humidity < 95% Non-Condensing
Enclosure Powder-Coated MS Sheet
Cooling Forced Air Cooling with Thermal Sensors
Dimensions Model-dependent
Mounting Floor Standing
PROTECTIONS
Input Over/Under Voltage
Output Overload
Output Short Circuit
DC Reverse Polarity
Battery Deep Discharge
Battery Overcharge
Over Temperature Protection
Output Over Voltage
INDICATIONS & ALARMS
Mains ON
Inverter ON
Charging ON
Battery Low Alarm
Fault Indication
Overload Alarm
Audio + Visual Fault Alerts
OPTIONAL FEATURES
Auto-Bypass System
RS232 / RS485 Communication Port
SNMP Monitoring Module
Emergency Lift Lowering Interface
Extended Battery Backup Support
Fire-Retardant Cabinet (FR Grade)

Product visuals may differ from the actual item.*

10 kVA LIFT INVERTER

Application areas

➤ Mid-Rise Residential Elevators
➤ Commercial Passenger Lifts
➤ Hospital Bed Elevators
➤ Goods Lifts (Medium Duty)
➤ Hydraulic Lifts with higher load
➤ Machine Room & Machine Room-Less Lifts (MR/MR-L)
➤ Corporate Building Elevators
➤ Escalator Control Panels

Product features:

➤ Advanced DSP-based Pure Sine Wave Inverter for elevator-grade reliability
➤ High Surge Handling to support heavy starting torque of lift motors
➤ Ultra-Fast Transfer Time (<10 ms) — zero jerk movement during power failure
➤ Wide Input Voltage Range, suitable for areas with fluctuating supply
➤ Robust Output Isolation Transformer for enhanced safety
➤ Intelligent Multi-Stage CC-CV Battery Charging
➤ Heavy-Duty IGBT Power Stage ensures long life
➤ Smooth Motor Control with low harmonic distortion
➤ Designed for continuous commercial operation
➤ User-Friendly LCD with complete system status
➤ Comprehensive Electrical Protections
➤ Compatible with SMF, VRLA & LiFePO4 battery configurations
➤ Engineered for zero-maintenance operation in lifts

10 kVA LIFT INVERTER — TECHNICAL SPECIFICATIONS
Model 10 kVA Lift Inverter (10,000 VA)
AC INPUT
Input Voltage 230V / 415V AC (Model Variant)
Voltage Tolerance ± 20%
Frequency 50Hz ± 6%
Phase Single Phase / Three Phase Options
DC INPUT / BATTERY
DC Voltage 96V / 120V (Model Dependent)
Battery Type SMF / VRLA / Lithium (LiFePO4)
Charger Type Intelligent CC-CV Charger
Charging Current 15A / 20A / 25A
INVERTER
Technology DSP-Controlled IGBT PWM
Output Voltage 230V AC (1Ø)
Output Regulation ±1%
Frequency 50Hz ± 0.1Hz
Waveform Pure Sine Wave
Efficiency > 92%
THD (Linear Load) < 3%
Overload Capability 110% for 10 minutes
150% for 1 minute
Crest Factor 3:1
Motor Starting High surge rating
Isolation Galvanic Isolation Transformer
Noise Level < 50 dB at 1 meter
DISPLAY
LCD Display Shows Input Voltage
Output Voltage
Output Current / Load %
Battery Voltage
Battery Charging Status
Temperature Status
Faults & Alarms
GENERAL
Operating Temperature 0°C – 45°C
Humidity < 95% Non-condensing
Cooling Forced Air Cooling with Temperature Control
Enclosure Heavy-Duty Powder-Coated MS Cabinet
Installation Floor Mount
PROTECTIONS
Protections Overload
Short Circuit
Over Temperature
Input Over/Under Voltage
Output Over Voltage
Battery Deep Discharge
Battery Overcharge
Reverse Polarity Protection
INDICATIONS & ALARMS
Indicators Mains ON
Inverter ON
Charger ON
Battery Low Alarm
Overload Alarm
System Fault Buzzer
LCD Fault Messages
OPTIONAL FEATURES
Options Automatic Static Bypass
RS232 / RS485 Port
SNMP Monitoring Module
Lift Emergency Rescue Mode
Advanced Logging Module
Fire-Retardant Cabinet
Extended Battery Bank

Product visuals may differ from the actual item.*

15 kVA LIFT INVERTER

Application areas

➤ High-Rise Residential Elevators
➤ Commercial Passenger Lifts (Heavy Duty)
➤ Hospital Bed Elevators (High Capacity)
➤ Industrial Goods Lifts
➤ Hydraulic Lifts with large motor loads
➤ MRL Elevators (Machine Room Less)
➤ Corporate & Institutional Buildings
➤ Multi-Lift Installations (Group Control Setup)

Product features:

➤ DSP-Based Pure Sine Wave Inverter designed for heavy-duty elevator motors
➤ High Surge Rating supports induction motor startup smoothly
➤ Ultra-Fast Transfer (<10 ms) ensures jerk-free lift movement
➤ Wide Input Voltage Handling for unstable power grids
➤ Robust Isolation Transformer ensures motor safety
➤ Intelligent Multi-Stage Battery Charging (CC-CV)
➤ Heavy-Duty IGBT Power Stage built for continuous commercial operation
➤ Low Harmonic Output ensures smooth elevator operation
➤ High Efficiency design, reducing heat and improving reliability
➤ Compatibility with SMF, VRLA & Lithium (LiFePO4) batteries
➤ Smart LCD Display for full system monitoring
➤ Strong thermal management with intelligent cooling
➤ Long life, low maintenance system engineered for lifts

15 kVA LIFT INVERTER — TECHNICAL SPECIFICATIONS
Model 15 kVA Lift Inverter (15,000 VA)
AC INPUT
Input Voltage 415V AC ± 20%
Input Frequency 50Hz ± 6%
Phase Three Phase Input
Input Power Factor > 0.98
DC INPUT / BATTERY
DC Voltage 180V / 192V (Model Variant)
Battery Type SMF / VRLA / LiFePO4
Charging System Smart CC-CV Technology
Charging Current 20A / 25A / 30A (Selectable)
INVERTER
Technology DSP-Controlled, IGBT PWM
Output Voltage 230V AC (Single Phase Output)
Voltage Regulation ±1%
Frequency 50Hz ± 0.1Hz
Waveform Pure Sine Wave
Efficiency > 92%
THD (Linear Load) < 3%
Overload Capability 110% for 10 min
150% for 1 min
Crest Factor 3:1
Motor Starting Capacity High Surge Rating
Isolation Output Isolation Transformer (Full Galvanic Isolation)
Acoustic Noise < 50 dB at 1 meter
DISPLAY
LCD Display Shows R, Y, B Input Voltages
Output Voltage
Output Load %
Battery Voltage
Battery Charging Status
System Temperature
Fault Indicators
GENERAL
Operating Temperature 0°C – 45°C
Humidity < 95% Non-Condensing
Cooling Intelligent Forced Air Cooling
Enclosure Powder-Coated Heavy-Duty MS Cabinet
Mounting Floor Standing Design
PROTECTIONS
Protections Input Over/Under Voltage
Output Overload
Output Short Circuit
Battery Deep Discharge
Battery Overcharge
Reverse Polarity
Over Temperature Protection
Output Over Voltage
Phase Failure Protection
INDICATIONS & ALARMS
Indicators & Alarms Mains ON
Inverter ON
Charging ON
Battery Low Alarm
System Fault Alarm
Overload Warning
Audio + Visual Alerts
OPTIONAL FEATURES
Options Automatic Static Bypass
RS232 / RS485 Port
SNMP Card for Remote Monitoring
Emergency Lift Rescue Mode Integration
Extended Battery Backup Options
Fire-Resistant Cabinet
Event & Fault Logging Module