LIFT POWER BACKUP SYSTEM
Product visuals may differ from the actual item.*
2.2 kVA LIFT INVERTER
Application areas
➤ Residential Elevators
➤ Hydraulic Lifts
➤ Commercial Low-Rise Buildings
➤ Hospital & Clinic Lifts
➤ Villa Elevators
➤ Home Dumbwaiter Lifts
➤ Goods Lifts (Small Capacity)
Product features:
➤ Advanced DSP-based Pure Sine Wave Technology for precise control & smooth lift operation
➤ High Starting Torque Support for elevator motors
➤ Fast Changeover (<10 ms) ensures lift doesn’t jerk or stop during power failure
➤ Compatible with both Single Phase Input & Single Phase Output
➤ High Surge Capability to start lift motors without overloading
➤ Wide Input Voltage Range for unstable power conditions
➤ Inbuilt MCB Protection & Smart LCD Display
➤ Pure Sine Wave Output ensures smooth motor rotation
➤ Intelligent Battery Charging System for extended battery life
➤ Overload & Short Circuit Protection
➤ Inbuilt Isolation for enhanced safety
➤ Customizable Backup Options as per lift requirement
➤ Easy Installation & Maintenance-Friendly Design
| PARAMETER — TECHNICAL SPECIFICATION | |
|---|---|
| Model | 2.2 kVA Lift Inverter |
| Rating | 2200 VA |
| AC INPUT | |
| Voltage | 230V AC ± 20% |
| Frequency | 50Hz ± 6% |
| Phase | Single Phase |
| DC INPUT / BATTERY | |
| DC Voltage | 24V DC |
| Battery Type | SMF / VRLA / Lithium Compatible |
| Charger Type | CC-CV Intelligent Charger |
| Charging Current | 10A (Adjustable) |
| INVERTER | |
| Technology | DSP-Based PWM Sine Wave |
| Output Voltage | 230V AC |
| Voltage Regulation | ±1% |
| Output Frequency | 50Hz ± 0.1Hz |
| Waveform | Pure Sine Wave |
| Efficiency | > 90% |
| Overload | 110% for 5 minutes, 150% for 30 seconds |
| Motor Starting Capability | High surge support |
| Crest Factor | 3:1 |
| DISPLAY | |
| LCD Display Showing |
Input Voltage Output Voltage Output Load % Battery Voltage Battery Status Fault Conditions |
| GENERAL | |
| Operating Temperature | 0°C – 45°C |
| Humidity | < 95% Non-Condensing |
| Noise Level | < 50 dB at 1 meter |
| Enclosure | Powder-Coated MS Sheet |
| Cooling | Forced Air Cooling |
| PROTECTIONS | |
|
Input Over/Under Voltage Output Overload Short Circuit Protection Battery Deep Discharge Battery Overcharge Over Temperature Protection Reverse Polarity Protection |
|
| INDICATIONS & ALARMS | |
|
Mains ON Inverter ON Battery Low Overload Alarm Fault LED + Buzzer Charging ON |
|
| OPTIONAL FEATURES | |
|
RS232 / RS485 Communication SNMP Module Auto-Bypass System Fire-Retardant Enclosure High Backup (Extended Battery Bank) |
|
Product visuals may differ from the actual item.*
3.5 kVA LIFT INVERTER
Application areas
➤ Residential & Mid-Rise Building Elevators
➤ Home Lifts & Hydraulic Lifts
➤ Small Commercial Elevators
➤ Hospital Bed Lifts (Compact Models)
➤ Goods Lifts (Light Duty)
➤ Dumbwaiter Elevators
➤ Escalator Control Backup Panels
Product features:
➤ DSP-controlled Pure Sine Wave Output for smooth elevator motor operation
➤ High Surge Capability to handle motor starting current
➤ Ultra-Fast Transfer Time (<10 ms) — ensures lift does not jerk
➤ Wide Input Voltage Range suitable for low grid areas
➤ Rugged Design for commercial elevator usage
➤ Intelligent CC-CV Battery Charging System
➤ Pure Sine Output ensures smooth & vibration-free lift travel
➤ Inbuilt MCB & Multiple Electronic Protections
➤ Heavy-Duty Output Transformer for reliability
➤ Compatible with SMF, VRLA & Lithium (LiFePO4) battery banks
➤ Easy Installation & Low Maintenance Design
➤ Optional Auto-Bypass for enhanced safety
| PARAMETER — TECHNICAL SPECIFICATION | |
|---|---|
| Model | 3.5 kVA Lift Inverter |
| Rating | 3500 VA |
| AC INPUT | |
| Voltage | 230V AC ± 20% |
| Frequency | 50Hz ± 6% |
| Phase | Single Phase |
| DC INPUT / BATTERY | |
| DC Voltage | 48V DC |
| Battery Type | SMF / VRLA / Lithium Compatible |
| Charger Type | Intelligent CC-CV Charger |
| Charging Current | 10A / 15A (Model Dependent) |
| INVERTER | |
| Technology | DSP-Based IGBT PWM |
| Output Voltage | 230V AC |
| Voltage Regulation | ±1% |
| Output Frequency | 50Hz ± 0.1Hz |
| Waveform | Pure Sine Wave |
| Efficiency | > 90% |
| Harmonic Distortion | <3% on Linear Load |
| Overload | 110% for 10 minutes, 150% for 30 seconds |
| Motor Starting Capability | High surge support |
| Crest Factor | 3:1 |
| Isolation | Output Isolation Transformer |
| DISPLAY | |
| LCD Display Showing |
Input Voltage Output Voltage Output Current / Load % Battery Voltage System Temperature Fault Conditions |
| GENERAL | |
| Operating Temperature | 0°C – 45°C |
| Humidity | < 95% Non-Condensing |
| Noise Level | < 50 dB at 1 meter |
| Enclosure | Powder-Coated Metal Sheet |
| Cooling | Intelligent Forced Cooling System |
| PROTECTIONS | |
|
Mains Over/Under Voltage Output Overload Output Short Circuit Battery Deep Discharge Battery Overcharge Heat Protection Reverse Battery Polarity Output Over Temperature |
|
| INDICATIONS & ALARMS | |
|
Mains ON LED Inverter ON LED Charging ON LED Battery Low Alarm Overload Alarm Fault Indication + Buzzer |
|
| OPTIONAL FEATURES | |
|
Auto-Bypass RS232 / RS485 Communication SNMP Interface Emergency Rescue Device (Lift Lowering) Extended Battery Bank Options Fire-Retardant Cabinet |
|
Product visuals may differ from the actual item.*
5 kVA LIFT INVERTER
Application areas
➤ Residential Lifts (High Load)
➤ Commercial Building Elevators
➤ Small Industrial Goods Lifts
➤ Hospital Duty Elevators
➤ Hydraulic Home Elevators
➤ Passenger Lifts up to 6–8 passengers
➤ Escalators & Lift Control Panels
➤ Freight Lifts with Light Load Capacity
Product features:
➤ Advanced DSP-based Pure Sine Wave technology
➤ High Starting Torque Support for lift motors
➤ Ultra-Fast Transfer (<10 ms) ensuring jerk-free lift operation
➤ High Surge Capacity ideal for induction motor startup
➤ Wide Input Voltage Range for unstable mains supply
➤ Robust Output Isolation Transformer
➤ Intelligent CC-CV Charger for long battery life
➤ Pure Sine Wave output for smooth motor control
➤ Heavy-Duty IGBT-based Inverter Stage
➤ Overload, Short-Circuit & Over Temperature Protection
➤ Compatible with SMF/VRLA/LiFePO4 battery banks
➤ Engineered for continuous commercial use
➤ Easy front-access design for maintenance
➤ Optional Auto-Bypass for seamless lift operation
| PARAMETER — TECHNICAL SPECIFICATION | |
|---|---|
| Model | 5 kVA Lift Inverter |
| Rating | 5000 VA |
| AC INPUT | |
| Voltage | 230V AC ± 20% |
| Frequency | 50Hz ± 6% |
| Phase | Single Phase |
| DC INPUT / BATTERY | |
| DC Voltage | 48V / 96V (Model Variant) |
| Battery Type | SMF / VRLA / Lithium (LiFePO4) |
| Charger Type | Intelligent CC-CV Charging |
| Charging Current | 12A / 15A / 20A |
| INVERTER | |
| Technology | DSP + IGBT PWM Controlled |
| Output Voltage | 230V AC |
| Voltage Regulation | ±1% |
| Output Frequency | 50Hz ± 0.1Hz |
| Waveform | Pure Sine Wave |
| Efficiency | > 90% |
| Harmonic Distortion | <3% on Linear Load |
| Overload |
110% for 10 min 150% for 30 sec |
| Crest Factor | 3:1 |
| Motor Starting Capability | Strong surge support |
| Isolation | Galvanic Isolation Output Transformer |
| Audible Noise | <50 dB at 1 meter |
| DISPLAY | |
| LCD Display Shows |
Input Voltage Output Voltage Output Load % Battery Voltage System Temperature Charging Status Faults & Alarms |
| GENERAL | |
| Operating Temperature | 0°C – 45°C |
| Humidity | < 95% Non-Condensing |
| Enclosure | Powder-Coated MS Sheet |
| Cooling | Forced Air Cooling with Thermal Sensors |
| Dimensions | Model-dependent |
| Mounting | Floor Standing |
| PROTECTIONS | |
|
Input Over/Under Voltage Output Overload Output Short Circuit DC Reverse Polarity Battery Deep Discharge Battery Overcharge Over Temperature Protection Output Over Voltage |
|
| INDICATIONS & ALARMS | |
|
Mains ON Inverter ON Charging ON Battery Low Alarm Fault Indication Overload Alarm Audio + Visual Fault Alerts |
|
| OPTIONAL FEATURES | |
|
Auto-Bypass System RS232 / RS485 Communication Port SNMP Monitoring Module Emergency Lift Lowering Interface Extended Battery Backup Support Fire-Retardant Cabinet (FR Grade) |
|
Product visuals may differ from the actual item.*
10 kVA LIFT INVERTER
Application areas
➤ Mid-Rise Residential Elevators
➤ Commercial Passenger Lifts
➤ Hospital Bed Elevators
➤ Goods Lifts (Medium Duty)
➤ Hydraulic Lifts with higher load
➤ Machine Room & Machine Room-Less Lifts (MR/MR-L)
➤ Corporate Building Elevators
➤ Escalator Control Panels
Product features:
➤ Advanced DSP-based Pure Sine Wave Inverter for elevator-grade reliability
➤ High Surge Handling to support heavy starting torque of lift motors
➤ Ultra-Fast Transfer Time (<10 ms) — zero jerk movement during power failure
➤ Wide Input Voltage Range, suitable for areas with fluctuating supply
➤ Robust Output Isolation Transformer for enhanced safety
➤ Intelligent Multi-Stage CC-CV Battery Charging
➤ Heavy-Duty IGBT Power Stage ensures long life
➤ Smooth Motor Control with low harmonic distortion
➤ Designed for continuous commercial operation
➤ User-Friendly LCD with complete system status
➤ Comprehensive Electrical Protections
➤ Compatible with SMF, VRLA & LiFePO4 battery configurations
➤ Engineered for zero-maintenance operation in lifts
| 10 kVA LIFT INVERTER — TECHNICAL SPECIFICATIONS | |
|---|---|
| Model | 10 kVA Lift Inverter (10,000 VA) |
| AC INPUT | |
| Input Voltage | 230V / 415V AC (Model Variant) |
| Voltage Tolerance | ± 20% |
| Frequency | 50Hz ± 6% |
| Phase | Single Phase / Three Phase Options |
| DC INPUT / BATTERY | |
| DC Voltage | 96V / 120V (Model Dependent) |
| Battery Type | SMF / VRLA / Lithium (LiFePO4) |
| Charger Type | Intelligent CC-CV Charger |
| Charging Current | 15A / 20A / 25A |
| INVERTER | |
| Technology | DSP-Controlled IGBT PWM |
| Output Voltage | 230V AC (1Ø) |
| Output Regulation | ±1% |
| Frequency | 50Hz ± 0.1Hz |
| Waveform | Pure Sine Wave |
| Efficiency | > 92% |
| THD (Linear Load) | < 3% |
| Overload Capability |
110% for 10 minutes 150% for 1 minute |
| Crest Factor | 3:1 |
| Motor Starting | High surge rating |
| Isolation | Galvanic Isolation Transformer |
| Noise Level | < 50 dB at 1 meter |
| DISPLAY | |
| LCD Display Shows |
Input Voltage Output Voltage Output Current / Load % Battery Voltage Battery Charging Status Temperature Status Faults & Alarms |
| GENERAL | |
| Operating Temperature | 0°C – 45°C |
| Humidity | < 95% Non-condensing |
| Cooling | Forced Air Cooling with Temperature Control |
| Enclosure | Heavy-Duty Powder-Coated MS Cabinet |
| Installation | Floor Mount |
| PROTECTIONS | |
| Protections |
Overload Short Circuit Over Temperature Input Over/Under Voltage Output Over Voltage Battery Deep Discharge Battery Overcharge Reverse Polarity Protection |
| INDICATIONS & ALARMS | |
| Indicators |
Mains ON Inverter ON Charger ON Battery Low Alarm Overload Alarm System Fault Buzzer LCD Fault Messages |
| OPTIONAL FEATURES | |
| Options |
Automatic Static Bypass RS232 / RS485 Port SNMP Monitoring Module Lift Emergency Rescue Mode Advanced Logging Module Fire-Retardant Cabinet Extended Battery Bank |
Product visuals may differ from the actual item.*
15 kVA LIFT INVERTER
Application areas
➤ High-Rise Residential Elevators
➤ Commercial Passenger Lifts (Heavy Duty)
➤ Hospital Bed Elevators (High Capacity)
➤ Industrial Goods Lifts
➤ Hydraulic Lifts with large motor loads
➤ MRL Elevators (Machine Room Less)
➤ Corporate & Institutional Buildings
➤ Multi-Lift Installations (Group Control Setup)
Product features:
➤ DSP-Based Pure Sine Wave Inverter designed for heavy-duty elevator motors
➤ High Surge Rating supports induction motor startup smoothly
➤ Ultra-Fast Transfer (<10 ms) ensures jerk-free lift movement
➤ Wide Input Voltage Handling for unstable power grids
➤ Robust Isolation Transformer ensures motor safety
➤ Intelligent Multi-Stage Battery Charging (CC-CV)
➤ Heavy-Duty IGBT Power Stage built for continuous commercial operation
➤ Low Harmonic Output ensures smooth elevator operation
➤ High Efficiency design, reducing heat and improving reliability
➤ Compatibility with SMF, VRLA & Lithium (LiFePO4) batteries
➤ Smart LCD Display for full system monitoring
➤ Strong thermal management with intelligent cooling
➤ Long life, low maintenance system engineered for lifts
| 15 kVA LIFT INVERTER — TECHNICAL SPECIFICATIONS | |
|---|---|
| Model | 15 kVA Lift Inverter (15,000 VA) |
| AC INPUT | |
| Input Voltage | 415V AC ± 20% |
| Input Frequency | 50Hz ± 6% |
| Phase | Three Phase Input |
| Input Power Factor | > 0.98 |
| DC INPUT / BATTERY | |
| DC Voltage | 180V / 192V (Model Variant) |
| Battery Type | SMF / VRLA / LiFePO4 |
| Charging System | Smart CC-CV Technology |
| Charging Current | 20A / 25A / 30A (Selectable) |
| INVERTER | |
| Technology | DSP-Controlled, IGBT PWM |
| Output Voltage | 230V AC (Single Phase Output) |
| Voltage Regulation | ±1% |
| Frequency | 50Hz ± 0.1Hz |
| Waveform | Pure Sine Wave |
| Efficiency | > 92% |
| THD (Linear Load) | < 3% |
| Overload Capability |
110% for 10 min 150% for 1 min |
| Crest Factor | 3:1 |
| Motor Starting Capacity | High Surge Rating |
| Isolation | Output Isolation Transformer (Full Galvanic Isolation) |
| Acoustic Noise | < 50 dB at 1 meter |
| DISPLAY | |
| LCD Display Shows |
R, Y, B Input Voltages Output Voltage Output Load % Battery Voltage Battery Charging Status System Temperature Fault Indicators |
| GENERAL | |
| Operating Temperature | 0°C – 45°C |
| Humidity | < 95% Non-Condensing |
| Cooling | Intelligent Forced Air Cooling |
| Enclosure | Powder-Coated Heavy-Duty MS Cabinet |
| Mounting | Floor Standing Design |
| PROTECTIONS | |
| Protections |
Input Over/Under Voltage Output Overload Output Short Circuit Battery Deep Discharge Battery Overcharge Reverse Polarity Over Temperature Protection Output Over Voltage Phase Failure Protection |
| INDICATIONS & ALARMS | |
| Indicators & Alarms |
Mains ON Inverter ON Charging ON Battery Low Alarm System Fault Alarm Overload Warning Audio + Visual Alerts |
| OPTIONAL FEATURES | |
| Options |
Automatic Static Bypass RS232 / RS485 Port SNMP Card for Remote Monitoring Emergency Lift Rescue Mode Integration Extended Battery Backup Options Fire-Resistant Cabinet Event & Fault Logging Module |