LIFT POWER BACKUP SYSTEM
Product visuals may differ from the actual item.*
10 to 350 KVA LIFT INVERTER
Application areas
➤ Residential Elevators
➤ Hydraulic Lifts
➤ Commercial Low-Rise Buildings
➤ Hospital & Clinic Lifts
➤ Villa Elevators
➤ Home Dumbwaiter Lifts
➤ Goods Lifts (Small Capacity)
Product features:
➤ Advanced DSP-based Pure Sine Wave Technology for precise control & smooth lift operation
➤ High Starting Torque Support for elevator motors
➤ Fast Changeover (<10 ms) ensures lift doesn’t jerk or stop during power failure
➤ Compatible with both Single Phase Input & Single Phase Output
➤ High Surge Capability to start lift motors without overloading
➤ Wide Input Voltage Range for unstable power conditions
➤ Inbuilt MCB Protection & Smart LCD Display
➤ Pure Sine Wave Output ensures smooth motor rotation
➤ Intelligent Battery Charging System for extended battery life
➤ Overload & Short Circuit Protection
➤ Inbuilt Isolation for enhanced safety
➤ Customizable Backup Options as per lift requirement
➤ Easy Installation & Maintenance-Friendly Design
| PARAMETER — TECHNICAL SPECIFICATION | |
|---|---|
| Model | 10 to 350 KVA Lift Inverter |
| Rating | 2200 VA |
| AC INPUT | |
| Voltage | 230V AC ± 20% |
| Frequency | 50Hz ± 6% |
| Phase | Single Phase |
| DC INPUT / BATTERY | |
| DC Voltage | 24V DC |
| Battery Type | SMF / VRLA / Lithium Compatible |
| Charger Type | CC-CV Intelligent Charger |
| Charging Current | 10A (Adjustable) |
| INVERTER | |
| Technology | DSP-Based PWM Sine Wave |
| Output Voltage | 230V AC |
| Voltage Regulation | ±1% |
| Output Frequency | 50Hz ± 0.1Hz |
| Waveform | Pure Sine Wave |
| Efficiency | > 90% |
| Overload | 110% for 5 minutes, 150% for 30 seconds |
| Motor Starting Capability | High surge support |
| Crest Factor | 3:1 |
| DISPLAY | |
| LCD Display Showing | Input Voltage Output Voltage Output Load % Battery Voltage Battery Status Fault Conditions |
| GENERAL | |
| Operating Temperature | 0°C – 45°C |
| Humidity | < 95% Non-Condensing |
| Noise Level | < 50 dB at 1 meter |
| Enclosure | Powder-Coated MS Sheet |
| Cooling | Forced Air Cooling |
| PROTECTIONS | |
| Input Over/Under Voltage Output Overload Short Circuit Protection Battery Deep Discharge Battery Overcharge Over Temperature Protection Reverse Polarity Protection | |
| INDICATIONS & ALARMS | |
| Mains ON Inverter ON Battery Low Overload Alarm Fault LED + Buzzer Charging ON | |
| OPTIONAL FEATURES | |
| RS232 / RS485 Communication SNMP Module Auto-Bypass System Fire-Retardant Enclosure High Backup (Extended Battery Bank) | |